Improper access control in Siemens SENTRON 7KM PAC3120 AC/DC
Key facts
- Attack vector
- Physical
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-284.
Summary
A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | SENTRON 7KM PAC3120 AC/DC | V3.2.3 to before V3.2.4 | V3.2.4 | Patch available | CNA |
| Siemens | SENTRON 7KM PAC3120 DC | V3.2.3 to before V3.2.4 | V3.2.4 | Patch available | CNA |
| Siemens | SENTRON 7KM PAC3220 AC/DC | V3.2.3 to before V3.2.4 | V3.2.4 | Patch available | CNA |
| Siemens | SENTRON 7KM PAC3220 DC | V3.2.3 to before V3.2.4 | V3.2.4 | Patch available | CNA |
- SENTRON 7KM PAC3120 AC/DC VendorSiemens Affected V3.2.3 to before V3.2.4 Fixed in V3.2.4 Patch available CNA
- SENTRON 7KM PAC3120 DC VendorSiemens Affected V3.2.3 to before V3.2.4 Fixed in V3.2.4 Patch available CNA
- SENTRON 7KM PAC3220 AC/DC VendorSiemens Affected V3.2.3 to before V3.2.4 Fixed in V3.2.4 Patch available CNA
- SENTRON 7KM PAC3220 DC VendorSiemens Affected V3.2.3 to before V3.2.4 Fixed in V3.2.4 Patch available CNA
Remediation
- Fix · CNA SENTRON 7KM PAC3120 AC/DC (Siemens) Fixed in V3.2.4
- Fix · CNA SENTRON 7KM PAC3120 DC (Siemens) Fixed in V3.2.4
- Fix · CNA SENTRON 7KM PAC3220 AC/DC (Siemens) Fixed in V3.2.4
- Fix · CNA SENTRON 7KM PAC3220 DC (Siemens) Fixed in V3.2.4
Timeline
- 2026-10-02 Threatist record created from CVE-2024-21483
- 2026-10-03 Alias added: GHSA-cc9x-2646-xv35
References
More Siemens vulnerabilities
- TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
- TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
- TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
- TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
- TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
- TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
Sources
- CVE-2024-21483 · CVE Program
- CVE-2024-21483 · NVD
- FIRST EPSS
- GHSA-cc9x-2646-xv35 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences