Read the docs
TI-2024-19026 Aliases CVE-2024-28809GHSA-qm4j-mqq4-36gx

An issue was discovered in Infinera hiT 7300 5.60.50.

Priority LOW 39CWE-312Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure, Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-312 and CWE-798.

Summary

An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00174 6th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:nokia:hit_7300_firmware:5.60.50:*:*:*:*:*:*:*5.60.50VulnerableNokia
cpe:2.3:h:nokia:hit_7300:-:*:*:*:*:*:*:*not specified by NVDRunning onNokia
  • cpe:2.3:o:nokia:hit_7300_firmware:5.60.50:*:*:*:*:*:*:* Versions 5.60.50 Vulnerable ·Nokia
  • cpe:2.3:h:nokia:hit_7300:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Nokia

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-28809
  2. 2026-10-03 Alias added: GHSA-qm4j-mqq4-36gx

References

  • TI-2024-19029 An issue was discovered in Infinera hiT 7300 5.60.50. CVSS 3.1HIGH 8.8
  • TI-2024-19030 An issue was discovered in Infinera hiT 7300 5.60.50. CVSS 3.1HIGH 8.4
  • TI-2024-19027 An issue was discovered in Infinera hiT 7300 5.60.50. CVSS 3.1MEDIUM 6.6
  • TI-2024-19024 An issue was discovered in Infinera hiT 7300 5.60.50. CVSS 3.1MEDIUM 6.5
  • TI-2024-19028 An issue was discovered in Infinera hiT 7300 5.60.50. CVSS 3.1LOW 3.3
  • TI-2024-19025 An issue was discovered in Infinera hiT 7300 5.60.50. CVSS 3.1LOW 2.7