Out-of-bounds read in Siemens Simcenter Femap
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Passive
- Attack complexity
- High
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Simcenter Femap | before V2406 | V2406 | Patch available | CNA |
- Simcenter Femap VendorSiemens Affected before V2406 Fixed in V2406 Patch available CNA
Remediation
- Fix · CNA Simcenter Femap (Siemens) Fixed in V2406
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Simcenter Femap V2406
12 records Highest priority Priority LOW 12 LOW
Other records, highest priority first
- TI-2024-22164 Stack-based buffer overflow in Siemens Simcenter FemapPriority LOW 34
- TI-2024-21153 Out-of-bounds read in Siemens Simcenter FemapPriority LOW 34
- TI-2024-21152 Out-of-bounds read in Siemens Simcenter FemapPriority LOW 34
Timeline
- 2026-10-02 Threatist record created from CVE-2024-32055
- 2026-10-03 Alias added: GHSA-6qf3-f3mv-m6c2
References
More Siemens Ps/iges Parasolid Translator vulnerabilities
- TI-2024-21153 Out-of-bounds read in Siemens Simcenter Femap CVSS 4.0HIGH 7.3
- TI-2024-21152 Out-of-bounds read in Siemens Simcenter Femap CVSS 4.0HIGH 7.3
- TI-2024-21151 Out-of-bounds read in Siemens Simcenter Femap CVSS 4.0HIGH 7.3
- TI-2024-21150 Type confusion in Siemens Simcenter Femap CVSS 4.0HIGH 7.3
- TI-2024-21149 Type confusion in Siemens Simcenter Femap CVSS 4.0HIGH 7.3
- TI-2024-21148 Out-of-bounds read in Siemens Simcenter Femap CVSS 4.0HIGH 7.3
Sources
- CVE-2024-32055 · CVE Program
- CVE-2024-32055 · NVD
- FIRST EPSS
- GHSA-6qf3-f3mv-m6c2 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences