Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page…
Priority HIGH 70CWE-121Published · Updated
Key facts
- Attack vector
- Adjacent network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-121 and the CVSS impact.
Summary
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function.
Why it matters now
Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.05581 92nd percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-32293
- 2026-10-03 Alias added: GHSA-cqxr-3xmh-c26p
References
More Tenda W30e Firmware vulnerabilities
- TI-2026-28218 Tenda W30E V2.0 V16.01.0.21 was found to contain a command injection vulnerability in the… CVSS 3.1CRITICAL 9.8
- TI-2025-35439 Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17… CVSS 3.1CRITICAL 9.8
- TI-2024-21252 Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via… CVSS 3.1CRITICAL 9.8
- TI-2023-27351 Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability… CVSS 3.1CRITICAL 9.8
- TI-2023-26987 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. CVSS 3.1CRITICAL 9.8
- TI-2022-22455 Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2024-32293 · CVE Program
- CVE-2024-32293 · NVD
- FIRST EPSS
- GHSA-cqxr-3xmh-c26p · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences