OS command injection in Seiko Solutions Inc. SkyBridge MB-A100/MB-A110
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-78.
Summary
Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Seiko Solutions Inc. | SkyBridge MB-A100/MB-A110 | firmware Ver. 4.2.2 and earlier | — | No fix listed | CNA |
| Seiko Solutions Inc. | SkyBridge BASIC MB-A130 | firmware Ver. 1.5.5 and earlier | — | No fix listed | CNA |
- SkyBridge MB-A100/MB-A110 VendorSeiko Solutions Inc. Affected firmware Ver. 4.2.2 and earlier Fixed in — No fix listed CNA
- SkyBridge BASIC MB-A130 VendorSeiko Solutions Inc. Affected firmware Ver. 1.5.5 and earlier Fixed in — No fix listed CNA
CPE names CISA-ADP · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:* | not specified by CISA-ADP | — | Seiko Solutions Inc. |
| cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:* | not specified by CISA-ADP | — | Seiko Solutions Inc. |
- cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Seiko Solutions Inc.
- cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Seiko Solutions Inc.
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-32850
- 2026-10-03 Alias added: GHSA-rg5r-x6g3-c6xm
More Seiko Solutions Inc. vulnerabilities
- TI-2023-08623 Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. CVSS 3.1MEDIUM 6.5
- TI-2025-34591 OS command injection in Seiko Solutions Inc. SkyBridge BASIC MB-A130 CVSS 4.0CRITICAL 9.3
- TI-2022-16872 Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection… CVSS 3.1CRITICAL 9.8
- TI-2023-08693 Missing authentication in Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC… CVSS 3.1HIGH 8.6
- TI-2022-16869 Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain a command… CVSS 3.1CRITICAL 9.8
- TI-2022-16873 Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2024-32850 · CVE Program
- CVE-2024-32850 · NVD
- FIRST EPSS
- GHSA-rg5r-x6g3-c6xm · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences