Stack-based buffer overflow in Siemens JT2Go
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-121 and the CVSS impact.
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | JT2Go | before V2312.0001 | V2312.0001 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.1 | before V14.1.0.13 | V14.1.0.13 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.2 | before V14.2.0.10 | V14.2.0.10 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.3 | before V14.3.0.7 | V14.3.0.7 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2312 | before V2312.0001 | V2312.0001 | Patch available | CNA |
- JT2Go VendorSiemens Affected before V2312.0001 Fixed in V2312.0001 Patch available CNA
- Teamcenter Visualization V14.1 VendorSiemens Affected before V14.1.0.13 Fixed in V14.1.0.13 Patch available CNA
- Teamcenter Visualization V14.2 VendorSiemens Affected before V14.2.0.10 Fixed in V14.2.0.10 Patch available CNA
- Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.7 Fixed in V14.3.0.7 Patch available CNA
- Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0001 Fixed in V2312.0001 Patch available CNA
Remediation
- Fix · CNA JT2Go (Siemens) Fixed in V2312.0001
- Fix · CNA Teamcenter Visualization V14.1 (Siemens) Fixed in V14.1.0.13
- Fix · CNA Teamcenter Visualization V14.2 (Siemens) Fixed in V14.2.0.10
- Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.7
- Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0001
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens JT2Go, Teamcenter Visualization V14.1 and 3 more products V14.1.0.13, V14.2.0.10 and 2 more versions
2 records Highest priority Priority LOW 2 LOW
Other records, highest priority first
- TI-2024-22543 Out-of-bounds write in Siemens JT2GoPriority LOW 36
Timeline
- 2026-10-02 Threatist record created from CVE-2024-34085
- 2026-10-03 Alias added: GHSA-55gp-7hw4-qj3q
References
More Siemens Jt2go vulnerabilities
- TI-2020-16414 NULL pointer dereference in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16413 Type confusion in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16410 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16408 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16419 Out-of-bounds read in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16418 Out-of-bounds write in Siemens JT2Go CVSS 3.1HIGH 8.8
Sources
- CVE-2024-34085 · CVE Program
- CVE-2024-34085 · NVD
- FIRST EPSS
- GHSA-55gp-7hw4-qj3q · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences