Read the docs
TI-2024-23282 Aliases CVE-2024-35210GHSA-x8h6-96m2-gv4q

Cleartext transmission of sensitive information in Siemens SINEC Traffic Analyzer

Priority LOW 28CWE-319Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
Low · Low · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-319.

Summary

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is not enforcing HSTS. This could allow an attacker to perform downgrade attacks exposing confidential information.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00149 4th percentileScored 2026-11-07
Fix Fixed SINEC Traffic Analyzer (Siemens): V1.2

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSINEC Traffic Analyzerbefore V1.2V1.2Patch availableCNA
  • SINEC Traffic Analyzer VendorSiemens Affected before V1.2 Fixed in V1.2 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*before 1.2VulnerableSiemens
  • cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:* Versions before 1.2 Vulnerable ·Siemens

Remediation

  • Fix · CNA SINEC Traffic Analyzer (Siemens) Fixed in V1.2

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens SINEC Traffic Analyzer V1.2

    7 records Highest priority Priority LOW 7 LOW

    Other records, highest priority first

    • TI-2024-23278 Insufficient session expiration in Siemens SINEC Traffic AnalyzerPriority LOW 39
    • TI-2024-23279 Cross-site request forgery in Siemens SINEC Traffic AnalyzerPriority LOW 38
    • TI-2024-23284 Improper input validation in Siemens SINEC Traffic AnalyzerPriority LOW 30

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-35210
  2. 2026-10-03 Alias added: GHSA-x8h6-96m2-gv4q

References

  • TI-2024-27930 Missing brute-force protection in Siemens SINEC Traffic Analyzer CVSS 4.0HIGH 8.7
  • TI-2025-27229 A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All… CVSS 4.0HIGH 8.8
  • TI-2024-23278 Insufficient session expiration in Siemens SINEC Traffic Analyzer CVSS 4.0HIGH 8.5
  • TI-2024-23279 Cross-site request forgery in Siemens SINEC Traffic Analyzer CVSS 4.0HIGH 8.5
  • TI-2024-27931 Improper access control in Siemens SINEC Traffic Analyzer CVSS 4.0HIGH 7.6
  • TI-2024-27929 Improper privilege management in Siemens SINEC Traffic Analyzer CVSS 4.0HIGH 7.5
See all 15 →