MileSight DeviceHub - CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Priority LOW 27CWE-79Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-79.
Summary
MileSight DeviceHub - CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00272 19th percentileScored 2026-11-07
Fix Fixed DeviceHub (MileSight): Upgrade to the latest version.
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Milesight | DeviceHub | v3.0.1-r1 for Ubuntu 20.04 to before Upgrade to the latest version. | Upgrade to the latest version. | Patch available | CNA |
- DeviceHub VendorMilesight Affected v3.0.1-r1 for Ubuntu 20.04 to before Upgrade to the latest version. Fixed in Upgrade to the latest version. Patch available CNA
Remediation
- Fix · CNA DeviceHub (MileSight) Fixed in Upgrade to the latest version.
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
MileSight DeviceHub Upgrade to the latest version.
6 records Highest priority Priority MEDIUM 4 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2024-18395 Path traversal in Milesight DeviceHubPriority MEDIUM 50
- TI-2024-24175 MileSight DeviceHub - CWE-330 Use of Insufficiently Random ValuesPriority MEDIUM 49
- TI-2024-24174 MileSight DeviceHub - CWE-305 Missing Authentication for Critical FunctionPriority MEDIUM 49
Timeline
- 2026-10-02 Threatist record created from CVE-2024-36392
- 2026-10-03 Alias added: GHSA-22p6-c9vr-pq5x
References
More Milesight Devicehub vulnerabilities
- TI-2024-18395 Path traversal in Milesight DeviceHub CVSS 3.1CRITICAL 9.8
- TI-2024-24175 MileSight DeviceHub - CWE-330 Use of Insufficiently Random Values CVSS 3.1CRITICAL 9.8
- TI-2024-24174 MileSight DeviceHub - CWE-305 Missing Authentication for Critical Function CVSS 3.1CRITICAL 10.0
- TI-2024-24177 MileSight DeviceHub - CWE-320: Key Management Errors CVSS 3.1CRITICAL 9.1
- TI-2024-24176 Improper input validation in Milesight DeviceHub CVSS 3.1HIGH 7.5
Sources
- CVE-2024-36392 · CVE Program
- CVE-2024-36392 · NVD
- FIRST EPSS
- GHSA-22p6-c9vr-pq5x · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences