Out-of-bounds read in Fuji Electric V-Server
Priority LOW 35CWE-125Published · Updated
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA.
Summary
There is an Out-of-bounds read vulnerability in V-Server (v4.0.19.0 and earlier) and V-Server Lite (v4.0.19.0 and earlier). If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00188 8th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Fuji Electric | V-Server | up to v4.0.19.0 | — | No fix listed | CNA |
| Fuji Electric | V-Server Lite | up to v4.0.19.0 | — | No fix listed | CNA |
- V-Server VendorFuji Electric Affected up to v4.0.19.0 Fixed in — No fix listed CNA
- V-Server Lite VendorFuji Electric Affected up to v4.0.19.0 Fixed in — No fix listed CNA
CPE names CISA-ADP · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:fujielectric:v-server_lite:*:*:*:*:*:*:*:* | — | — | Fuji Electric |
| cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:* | — | — | Fuji Electric |
- cpe:2.3:a:fujielectric:v-server_lite:*:*:*:*:*:*:*:* Versions — — ·Fuji Electric
- cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:* Versions — — ·Fuji Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-38658
- 2026-10-03 Alias added: GHSA-rjgc-mwc5-8g7j
References
More Fuji Electric vulnerabilities
- TI-2019-13257 Heap-based buffer overflow in Fuji Electric V-Server 4.0.6 and prior CVSS 3.1CRITICAL 9.8
- TI-2018-10620 Out-of-bounds read in Fuji Electric FRENIC LOADER of FRENIC-Mini , FRENIC-Mini… CVSS 3.0CRITICAL 9.8
- TI-2018-10653 Stack-based buffer overflow in Fuji Electric V-Server CVSS 3.1CRITICAL 9.8
- TI-2018-10643 Heap-based buffer overflow in Fuji Electric V-Server CVSS 3.1CRITICAL 9.8
- TI-2018-03956 Stack-based buffer overflow in Fuji Electric V-Server VPR CVSS 3.1CRITICAL 9.8
- TI-2018-10649 Out-of-bounds read in Fuji Electric V-Server CVSS 3.0CRITICAL 9.8
Sources
- CVE-2024-38658 · CVE Program
- CVE-2024-38658 · NVD
- FIRST EPSS
- GHSA-rjgc-mwc5-8g7j · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences