Broken or risky cryptographic algorithm in Siemens SmartClient modules Opcenter QL Home
Key facts
- Attack vector
- Adjacent network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- High
- Attack requirements
- Present
- Impact type
- Information disclosure
- Confidentiality · integrity · availability
- High · Low · Low
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-327.
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) | V13.2 to before V2506 | V2506 | Patch available | CNA |
| Siemens | SOA Audit | V13.2 to before V2506 | V2506 | Patch available | CNA |
| Siemens | SOA Cockpit | V13.2 to before V2506 | V2506 | Patch available | CNA |
- SmartClient modules Opcenter QL Home (SC) VendorSiemens Affected V13.2 to before V2506 Fixed in V2506 Patch available CNA
- SOA Audit VendorSiemens Affected V13.2 to before V2506 Fixed in V2506 Patch available CNA
- SOA Cockpit VendorSiemens Affected V13.2 to before V2506 Fixed in V2506 Patch available CNA
Remediation
- Fix · CNA SmartClient modules Opcenter QL Home (SC) (Siemens) Fixed in V2506
- Fix · CNA SOA Audit (Siemens) Fixed in V2506
- Fix · CNA SOA Cockpit (Siemens) Fixed in V2506
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens SOA Audit, SOA Cockpit, SmartClient modules Opcenter QL Home (SC) V2506
7 records Highest priority Priority LOW 7 LOW
Other records, highest priority first
- TI-2024-27999 Incorrect authorization in Siemens SmartClient modules Opcenter QL HomePriority LOW 32
- TI-2024-28002 A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All…Priority LOW 25
- TI-2024-28003 Information disclosure through error messages in Siemens SmartClient modules Opcenter QL…Priority LOW 23
Timeline
- 2026-10-02 Threatist record created from CVE-2024-41986
- 2026-10-03 Alias added: GHSA-fpgf-r359-892c
References
More Siemens Opcenter Quality vulnerabilities
- TI-2021-08882 A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS… CVSS 3.1CRITICAL 9.8
- TI-2023-24902 A vulnerability has been identified in Opcenter Execution Foundation (All versions <… CVSS 3.1HIGH 8.8
- TI-2023-24906 Improper input validation in Siemens Opcenter Execution Foundation CVSS 3.1HIGH 7.5
- TI-2023-24905 Buffer overflow in Siemens Opcenter Execution Foundation CVSS 3.1HIGH 7.5
- TI-2020-06109 Uncontrolled resource consumption in Siemens Opcenter Execution Discrete CVSS 3.1HIGH 8.2
- TI-2022-14854 Improper authentication in Siemens Opcenter Quality V13.1 CVSS 3.1HIGH 7.5
Sources
- CVE-2024-41986 · CVE Program
- CVE-2024-41986 · NVD
- FIRST EPSS
- GHSA-fpgf-r359-892c · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences