Out-of-bounds write in Siemens Teamcenter Visualization V14.2
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Passive
- Attack complexity
- High
- Attack requirements
- None
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 | before V14.2.0.14 | V14.2.0.14 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.3 | before V14.3.0.12 | V14.3.0.12 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2312 | before V2312.0008 | V2312.0008 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2302 | before V2302.0016 | V2302.0016 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2404 | before V2404.0005 | V2404.0005 | Patch available | CNA |
- Teamcenter Visualization V14.2 VendorSiemens Affected before V14.2.0.14 Fixed in V14.2.0.14 Patch available CNA
- Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.12 Fixed in V14.3.0.12 Patch available CNA
- Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0008 Fixed in V2312.0008 Patch available CNA
- Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0016 Fixed in V2302.0016 Patch available CNA
- Tecnomatix Plant Simulation V2404 VendorSiemens Affected before V2404.0005 Fixed in V2404.0005 Patch available CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* | before 2302.0016; 2303.0000 to before 2404.0005 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* Versions before 2302.0016; 2303.0000 to before 2404.0005 Vulnerable ·Siemens
Remediation
- Fix · CNA Teamcenter Visualization V14.2 (Siemens) Fixed in V14.2.0.14
- Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.12
- Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0008
- Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0016
- Fix · CNA Tecnomatix Plant Simulation V2404 (Siemens) Fixed in V2404.0005
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Teamcenter Visualization V14.2, Teamcenter Visualization V14.3 and 3 more products V14.2.0.14, V14.3.0.12 and 3 more versions
14 records Highest priority Priority LOW 14 LOW
Other records, highest priority first
- TI-2024-30518 Memory corruption in Siemens Teamcenter Visualization V14.2Priority LOW 34
- TI-2024-30517 Memory corruption in Siemens Teamcenter Visualization V14.2Priority LOW 34
- TI-2024-30516 Memory corruption in Siemens Teamcenter Visualization V14.2Priority LOW 34
Timeline
- 2026-10-02 Threatist record created from CVE-2024-45471
- 2026-10-03 Alias added: GHSA-c6h7-h5vq-2vwc
References
More Siemens Tecnomatix Plant Simulation vulnerabilities
- TI-2023-12136 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2021-08891 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2021-08890 Memory corruption in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2021-08889 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2024-15792 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
- TI-2024-15791 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
Sources
- CVE-2024-45471 · CVE Program
- CVE-2024-45471 · NVD
- FIRST EPSS
- GHSA-c6h7-h5vq-2vwc · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences