Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control.
Priority MEDIUM 41CWE-284Published · Updated
Key facts
- Attack vector
- Adjacent network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-284.
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00642 51st percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-46432
- 2026-10-03 Alias added: GHSA-hm2f-r463-q8wq
- 2026-10-21 EPSS moved to the 50th–90th percentile
References
More Tenda W18e Firmware vulnerabilities
- TI-2025-28764 An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code… CVSS 3.1CRITICAL 9.8
- TI-2023-24960 Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the… CVSS 3.1CRITICAL 9.8
- TI-2023-24961 Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName… CVSS 3.1CRITICAL 9.8
- TI-2025-21017 Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd… CVSS 3.1MEDIUM 6.5
- TI-2025-21016 Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID… CVSS 3.1MEDIUM 6.5
- TI-2025-02802 Tenda W18E setModules formSetAccountList stack-based overflow CVSS 4.0MEDIUM 5.3
Sources
- CVE-2024-46432 · CVE Program
- CVE-2024-46432 · NVD
- FIRST EPSS
- GHSA-hm2f-r463-q8wq · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences