Read the docs
TI-2024-31305 Aliases CVE-2024-46892GHSA-76f5-r74w-9h63

Insufficient session expiration in Siemens SINEC INS

Priority LOW 30CWE-613Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
None · High · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-613.

Summary

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00296 22nd percentileScored 2026-11-07
Fix Fixed SINEC INS (Siemens): V1.0 SP2 Update 3

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSINEC INSbefore V1.0 SP2 Update 3V1.0 SP2 Update 3Patch availableCNA
  • SINEC INS VendorSiemens Affected before V1.0 SP2 Update 3 Fixed in V1.0 SP2 Update 3 Patch available CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*before 1.0VulnerableSiemens
cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*1.0VulnerableSiemens
cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*1.0 sp1VulnerableSiemens
cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*1.0 sp2VulnerableSiemens
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*1.0 sp2_update_1VulnerableSiemens
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*1.0 sp2_update_2VulnerableSiemens
  • cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:* Versions before 1.0 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:* Versions 1.0 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:* Versions 1.0 sp1 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:* Versions 1.0 sp2 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:* Versions 1.0 sp2_update_1 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:* Versions 1.0 sp2_update_2 Vulnerable ·Siemens

Remediation

  • Fix · CNA SINEC INS (Siemens) Fixed in V1.0 SP2 Update 3

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens SINEC INS V1.0 SP2 Update 3

    6 records Highest priority Priority MEDIUM 2 MEDIUM, 4 LOW

    Other records, highest priority first

    • TI-2024-31303 OS command injection in Siemens SINEC INSPriority MEDIUM 42
    • TI-2024-31301 Path traversal in Siemens SINEC INSPriority MEDIUM 42
    • TI-2024-31304 Uncontrolled resource consumption in Siemens SINEC INSPriority LOW 37

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-46892
  2. 2026-10-03 Alias added: GHSA-76f5-r74w-9h63

References

  • TI-2022-01915 The c_rehash script allows command injection CVSS 3.1CRITICAL 9.8
  • TI-2023-23979 The HTTP/2 protocol allows a denial of service (server resource consumption) because… KEVCVSS 3.1HIGH 7.5
  • TI-2022-15935 The llhttp parser in the http module in Node v18.7.0 does not correctly handle header… CVSS 3.1MEDIUM 6.5
  • TI-2022-22181 Path traversal in Siemens SINEC INS CVSS 3.1CRITICAL 9.9
  • TI-2022-13925 The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does… CVSS 3.1MEDIUM 6.5
  • TI-2024-02335 Unbounded memory growth with session handling in TLSv1.3 CVSS 3.1MEDIUM 5.9
See all 42 →

Sources