Read the docs
TI-2024-35232 Aliases CVE-2024-52568GHSA-6w35-c59m-gf96

Use after free in Siemens Teamcenter Visualization V14.2

Priority LOW 33CWE-416Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Passive
Attack complexity
High
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-416 and the CVSS impact.

Summary

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-24244)

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00191 8th percentileScored 2026-11-07
Fix Fixed Teamcenter Visualization V14.2 (Siemens): V14.2.0.14Teamcenter Visualization V14.3 (Siemens): V14.3.0.12+4 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensTeamcenter Visualization V14.2before V14.2.0.14V14.2.0.14Patch availableCNA
SiemensTeamcenter Visualization V14.3before V14.3.0.12V14.3.0.12Patch availableCNA
SiemensTeamcenter Visualization V2312before V2312.0008V2312.0008Patch availableCNA
SiemensTeamcenter Visualization V2406before V2406.0005V2406.0005Patch availableCNA
SiemensTecnomatix Plant Simulation V2302before V2302.0018V2302.0018Patch availableCNA
SiemensTecnomatix Plant Simulation V2404before V2404.0007V2404.0007Patch availableCNA
  • Teamcenter Visualization V14.2 VendorSiemens Affected before V14.2.0.14 Fixed in V14.2.0.14 Patch available CNA
  • Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.12 Fixed in V14.3.0.12 Patch available CNA
  • Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0008 Fixed in V2312.0008 Patch available CNA
  • Teamcenter Visualization V2406 VendorSiemens Affected before V2406.0005 Fixed in V2406.0005 Patch available CNA
  • Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0018 Fixed in V2302.0018 Patch available CNA
  • Tecnomatix Plant Simulation V2404 VendorSiemens Affected before V2404.0007 Fixed in V2404.0007 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*before 2302.0018; 2404.0 to before 2404.0007VulnerableSiemens
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* Versions before 2302.0018; 2404.0 to before 2404.0007 Vulnerable ·Siemens

Remediation

  • Fix · CNA Teamcenter Visualization V14.2 (Siemens) Fixed in V14.2.0.14
  • Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.12
  • Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0008
  • Fix · CNA Teamcenter Visualization V2406 (Siemens) Fixed in V2406.0005
  • Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0018
  • Fix · CNA Tecnomatix Plant Simulation V2404 (Siemens) Fixed in V2404.0007

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens Teamcenter Visualization V14.2, Teamcenter Visualization V14.3 and 4 more products V14.2.0.14, V14.3.0.12 and 4 more versions

    10 records Highest priority Priority LOW 10 LOW

    Other records, highest priority first

    • TI-2024-35238 Out-of-bounds read in Siemens Teamcenter Visualization V14.2Priority LOW 34
    • TI-2024-35237 Out-of-bounds write in Siemens Teamcenter Visualization V14.2Priority LOW 34
    • TI-2024-35236 Stack-based buffer overflow in Siemens Teamcenter Visualization V14.2Priority LOW 34

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-52568
  2. 2026-10-03 Alias added: GHSA-6w35-c59m-gf96

References

  • TI-2023-12136 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2021-08891 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2021-08890 Memory corruption in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2021-08889 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2024-15792 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
  • TI-2024-15791 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
See all 85 →

Sources