Out-of-bounds read in Siemens Teamcenter Visualization V14.2
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Passive
- Attack complexity
- High
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 | before V14.2.0.14 | V14.2.0.14 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.3 | before V14.3.0.12 | V14.3.0.12 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2312 | before V2312.0008 | V2312.0008 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2302 | before V2302.0016 | V2302.0016 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2404 | before V2404.0005 | V2404.0005 | Patch available | CNA |
- Teamcenter Visualization V14.2 VendorSiemens Affected before V14.2.0.14 Fixed in V14.2.0.14 Patch available CNA
- Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.12 Fixed in V14.3.0.12 Patch available CNA
- Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0008 Fixed in V2312.0008 Patch available CNA
- Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0016 Fixed in V2302.0016 Patch available CNA
- Tecnomatix Plant Simulation V2404 VendorSiemens Affected before V2404.0005 Fixed in V2404.0005 Patch available CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* | 14.2 to before 14.2.0.14; 14.3 to before 14.3.0.12; 2312.0 to before 2312.0008 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* | 2302.0 to before 2302.0016; 2404.0 to before 2404.0005 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* Versions 14.2 to before 14.2.0.14; 14.3 to before 14.3.0.12; 2312.0 to before 2312.0008 Vulnerable ·Siemens
- cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* Versions 2302.0 to before 2302.0016; 2404.0 to before 2404.0005 Vulnerable ·Siemens
Remediation
- Fix · CNA Teamcenter Visualization V14.2 (Siemens) Fixed in V14.2.0.14
- Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.12
- Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0008
- Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0016
- Fix · CNA Tecnomatix Plant Simulation V2404 (Siemens) Fixed in V2404.0005
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Teamcenter Visualization V14.2, Teamcenter Visualization V14.3 and 3 more products V14.2.0.14, V14.3.0.12 and 3 more versions
2 records Highest priority Priority LOW 2 LOW
Other records, highest priority first
- TI-2024-35513 Stack-based buffer overflow in Siemens Teamcenter Visualization V14.2Priority LOW 33
Timeline
- 2026-10-02 Threatist record created from CVE-2024-53242
- 2026-10-03 Alias added: GHSA-cqxx-6m4f-2qcg
References
More Siemens Teamcenter Visualization vulnerabilities
- TI-2020-16414 NULL pointer dereference in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16413 Type confusion in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16410 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16408 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16419 Out-of-bounds read in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16418 Out-of-bounds write in Siemens JT2Go CVSS 3.1HIGH 8.8
Sources
- CVE-2024-53242 · CVE Program
- CVE-2024-53242 · NVD
- FIRST EPSS
- GHSA-cqxx-6m4f-2qcg · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences