Read the docs
TI-2025-00843 Aliases CVE-2025-1001GHSA-pv72-r6j5-c86m

Medixant RadiAnt DICOM Viewer Improper Certificate Validation

Priority LOW 25CWE-295Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
Active
Attack complexity
Low
Attack requirements
Present
Impact type
Spoofing
Confidentiality · integrity · availability
None · High · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-295.

Summary

Medixant RadiAnt DICOM Viewer is vulnerable due to failure of the update mechanism to verify the update server's certificate which could allow an attacker to alter network traffic and carry out a machine-in-the-middle attack (MITM). An attacker could modify the server's response and deliver a malicious update to the user.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00142 3rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
MedixantRadiAnt DICOM Viewer2024.02—No fix listedCNA
  • RadiAnt DICOM Viewer VendorMedixant Affected 2024.02 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-1001
  2. 2026-10-03 Alias added: GHSA-pv72-r6j5-c86m

References

  • TI-2026-14297 Medixant RadiAnt DICOM Out-of-bounds write CVSS 4.0MEDIUM 5.3