Heap memory corruption in ABB Terra AC wallbox

Priority LOW 27CWE-122Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
High
Attack requirements
Present
Impact type
—
Confidentiality · integrity · availability
None · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.0028 20th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
ABBTerra AC wallbox (UL40/80A)up to 1.8.32—No fix listedCNA
ABBTerra AC wallbox (UL32A)up to 1.8.2—No fix listedCNA
ABBTerra AC wallbox (MID/ CE) -Terra AC MIDup to 1.8.32—No fix listedCNA
ABBTerra AC wallbox (MID/ CE) -Terra AC Juno CEup to 1.8.32—No fix listedCNA
ABBTerra AC wallbox (MID/ CE) -Terra AC PTBup to 1.8.21—No fix listedCNA
ABBTerra AC wallbox (JP)up to 1.8.2—No fix listedCNA
  • Terra AC wallbox (UL40/80A) VendorABB Affected up to 1.8.32 Fixed in — No fix listed CNA
  • Terra AC wallbox (UL32A) VendorABB Affected up to 1.8.2 Fixed in — No fix listed CNA
  • Terra AC wallbox (MID/ CE) -Terra AC MID VendorABB Affected up to 1.8.32 Fixed in — No fix listed CNA
  • Terra AC wallbox (MID/ CE) -Terra AC Juno CE VendorABB Affected up to 1.8.32 Fixed in — No fix listed CNA
  • Terra AC wallbox (MID/ CE) -Terra AC PTB VendorABB Affected up to 1.8.21 Fixed in — No fix listed CNA
  • Terra AC wallbox (JP) VendorABB Affected up to 1.8.2 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-5517
  2. 2026-10-03 Alias added: GHSA-56rf-7q3j-jwjf

References

  • TI-2019-03985 ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
  • TI-2019-05127 The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is… CVSS 3.1HIGH 8.8
  • TI-2024-05845 Remote code execution in ABB ASPECT-Enterprise CVSS 4.0CRITICAL 9.4
  • TI-2024-34459 Service control in ABB ASPECT-Enterprise CVSS 4.0HIGH 8.8
  • TI-2024-05758 unauthorized file access CVSS 4.0CRITICAL 9.4
  • TI-2022-00806 ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access CVSS 3.1CRITICAL 9.8
See all 262 →