Read the docs
TI-2025-05201 Aliases CVE-2025-5763GHSA-rv56-m3gf-cgwm

Tenda CP3 apollo sub_F3C8C command injection

Priority MEDIUM 56CWE-74Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.

Summary

A vulnerability has been found in Tenda CP3 11.10.00.2311090948 and classified as critical. Affected by this vulnerability is the function sub_F3C8C of the file apollo. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.05077 92nd percentileScored 2026-11-07
Public exploit Yes 2 exploit referencesTagged by NVD and the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaCP311.10.00.2311090948—No fix listedCNA
  • CP3 VendorTenda Affected 11.10.00.2311090948 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:cp3_firmware:11.10.00.2311090948:*:*:*:*:*:*:*11.10.00.2311090948VulnerableTenda
cpe:2.3:h:tenda:cp3:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:cp3_firmware:11.10.00.2311090948:*:*:*:*:*:*:* Versions 11.10.00.2311090948 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:cp3:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-5763
  2. 2026-10-03 Alias added: GHSA-rv56-m3gf-cgwm

References

  • TI-2023-09136 Certain Tenda products are vulnerable to command injection. CVSS 3.1CRITICAL 9.8
  • TI-2023-14239 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 allows unauthenticated remote… CVSS 3.1CRITICAL 9.8
  • TI-2023-14238 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a… CVSS 3.1CRITICAL 9.8
  • TI-2023-14240 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against… CVSS 3.1CRITICAL 9.8
  • TI-2023-14241 Missing Support for an Integrity Check in Shenzen Tenda Technology IP Camera CP3… CVSS 3.1HIGH 7.5
  • TI-2023-14237 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a… CVSS 3.1HIGH 7.5

Sources