Read the docs
TI-2025-05388 Aliases CVE-2025-5965GHSA-4vv3-prpf-hx46

RCE via the backup feature available only to user with high privilege

Priority MEDIUM 56CWE-78Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-78.

Summary

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.28229 98th percentileScored 2026-11-07
Fix Fixed Infra Monitoring (Centreon): 25.10.2, 24.10.15, 24.04.19

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CentreonInfra Monitoring25.10.0 to before 25.10.2; 24.10.0 to before 24.10.15; 24.04.0 to before 24.04.1925.10.2, 24.10.15, 24.04.19Patch availableCNA
  • Infra Monitoring VendorCentreon Affected 25.10.0 to before 25.10.2; 24.10.0 to before 24.10.15; 24.04.0 to before 24.04.19 Fixed in 25.10.2, 24.10.15, 24.04.19 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*24.04.0 to before 24.04.19; 24.10.0 to before 24.10.15; 25.10.0 to before 25.10.2VulnerableCentreon
  • cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:* Versions 24.04.0 to before 24.04.19; 24.10.0 to before 24.10.15; 25.10.0 to before 25.10.2 Vulnerable ·Centreon

Remediation

  • Fix · CNA Infra Monitoring (Centreon) Fixed in 25.10.2, 24.10.15, 24.04.19

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Centreon Infra Monitoring 24.04.19, 24.10.15, 25.10.2

    4 records Highest priority Priority MEDIUM 1 MEDIUM, 3 LOW

    Other records, highest priority first

    • TI-2025-11490 Information disclosure on Administration parameters API endpointPriority LOW 30
    • TI-2025-11941 A user with elevated privileges can inject XSS in the Administration ACL Menus configuration pagePriority LOW 29
    • TI-2025-11484 A user with elevated privileges can inject XSS in the Hosts configuration parameters pagePriority LOW 29

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-5965
  2. 2026-10-03 Alias added: GHSA-4vv3-prpf-hx46

References

  • TI-2024-00588 SQL injection in Centreon CVSS 3.0HIGH 8.8
  • TI-2024-15236 SQL injection in Centreon CVSS 3.1HIGH 7.2
  • TI-2024-05319 SQL injection in Centreon CVSS 3.1HIGH 8.8
  • TI-2024-05317 SQL injection in Centreon CVSS 3.1HIGH 8.8
  • TI-2024-21388 A SQL Injection vulnerability exists in the updateServiceHost functionality in Centreon… CVSS 3.1CRITICAL 9.8
  • TI-2024-15239 SQL injection in Centreon CVSS 3.0HIGH 7.2
See all 55 →

Sources