Read the docs
TI-2025-06868 Aliases CVE-2025-7531GHSA-mhcw-3h6x-pvm7

Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow

Priority HIGH 73CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.01233 69th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaFH12021.2.0.14(408)—No fix listedCNA
  • FH1202 VendorTenda Affected 1.2.0.14(408) Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:*1.2.0.14(408)VulnerableTenda
cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:* Versions 1.2.0.14(408) Vulnerable ·Tenda
  • cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-7531
  2. 2026-10-03 Alias added: GHSA-mhcw-3h6x-pvm7

References

  • TI-2024-20306 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter… CVSS 3.1CRITICAL 9.8
  • TI-2024-20304 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability located in the deviceName… CVSS 3.1CRITICAL 9.8
  • TI-2024-20300 Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability in the entrys… CVSS 3.1CRITICAL 9.8
  • TI-2024-20295 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security parameter… CVSS 3.1CRITICAL 9.8
  • TI-2023-20199 Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via… CVSS 3.1CRITICAL 9.8
  • TI-2023-20198 Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered… CVSS 3.1CRITICAL 9.8
See all 62 →

Sources