Read the docs
TI-2025-07130 Aliases CVE-2025-7806GHSA-h65x-jjv9-8c48

Tenda FH451 SafeClientFilter fromSafeClientFilter stack-based overflow

Priority HIGH 71CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.01011 63rd percentileScored 2026-11-07
Public exploit Yes 2 exploit referencesTagged by NVD and the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaFH4511.0.0.9—No fix listedCNA
  • FH451 VendorTenda Affected 1.0.0.9 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:fh451_firmware:1.0.0.9:*:*:*:*:*:*:*1.0.0.9VulnerableTenda
cpe:2.3:h:tenda:fh451:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:fh451_firmware:1.0.0.9:*:*:*:*:*:*:* Versions 1.0.0.9 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:fh451:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-7806
  2. 2026-10-03 Alias added: GHSA-h65x-jjv9-8c48

References

  • TI-2024-30872 Tenda FH451 v1.0.0.9 has a command injection vulnerability in the formexeCommand function i CVSS 3.1CRITICAL 9.8
  • TI-2024-30870 Tenda FH451 v1.0.0.9 has a stack overflow vulnerability located in the RouteStatic function. CVSS 3.1CRITICAL 9.8
  • TI-2026-03940 Tenda FH451 WrlclientSet stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-03939 Tenda FH451 WrlExtraSet formWrlExtraSet stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-03173 Tenda FH451 AdvSetWan sub_3C434 stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-03172 Tenda FH451 setcfm fromSetCfm stack-based overflow CVSS 4.0HIGH 8.7
See all 27 →