TI-2025-07602 Aliases CVE-2025-8306GHSA-88wh-9r47-7g44

Improper Access Control in Asseco Infomedica Plus

Priority LOW 22CWE-1220Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
Low · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Asseco InfoMedica is a comprehensive solution used to manage both administrative and medical tasks in the healthcare sector. A low privileged user is able to obtain encoded passwords of all other accounts (including main administrator) due to lack of granularity in access control.  Chained exploitation of this vulnerability and CVE-2025-8307 allows an attacker to escalate privileges. This vulnerability has been fixed in versions 4.50.1 and 5.38.0

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00157 4th percentileScored 2026-11-07
Fix Fixed InfoMedica Plus (Asseco): 5.38.0, 4.50.1

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
AssecoInfoMedica Plus5.0.0 to before 5.38.0; 4.0.0 to before 4.50.15.38.0, 4.50.1Patch availableCNA
  • InfoMedica Plus VendorAsseco Affected 5.0.0 to before 5.38.0; 4.0.0 to before 4.50.1 Fixed in 5.38.0, 4.50.1 Patch available CNA

Remediation

  • Fix · CNA InfoMedica Plus (Asseco) Fixed in 5.38.0, 4.50.1

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Asseco InfoMedica Plus 4.50.1, 5.38.0

    2 records Highest priority Priority LOW 2 LOW

    Other records, highest priority first

    • TI-2025-07603 Recoverable passwords in Asseco Infomedica PlusPriority LOW 25

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-8306
  2. 2026-10-03 Alias added: GHSA-88wh-9r47-7g44

References

  • TI-2022-10314 The Reporting module in Aseco Lietuva document management system DVS Avilys before 3.5.58… CVSS 3.1HIGH 7.5
  • TI-2025-41095 Local File Inclusion in Contact Plan, E-Mail, SMS and Fax components in Asseco SEE Live… CVSS 3.1MEDIUM 6.5
  • TI-2025-07603 Recoverable passwords in Asseco Infomedica Plus CVSS 4.0MEDIUM 5.9
  • TI-2025-04109 Information disclosure via IDOR in Asseco AMDX CVSS 4.0MEDIUM 5.3
  • TI-2026-41696 Improper Restriction of XML External Entity Reference in proCertum SmartSign CVSS 4.0MEDIUM 4.8
  • TI-2026-41695 Arbitrary Path Execution via CPS URI in proCertum SmartSign CVSS 4.0MEDIUM 4.6

Sources