TI-2025-10188 Aliases CVE-2025-11120GHSA-62cc-6mpf-6rxc

Tenda AC8 SetServerConfig formSetServerConfig buffer overflow

Priority HIGH 73CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.04049 90th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaAC816.03.34.06—No fix listedCNA
  • AC8 VendorTenda Affected 16.03.34.06 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac18_firmware:16.03.34.06:*:*:*:*:*:*:*16.03.34.06VulnerableTenda
cpe:2.3:h:tenda:ac18:4.0:*:*:*:*:*:*:*4.0Running onTenda
  • cpe:2.3:o:tenda:ac18_firmware:16.03.34.06:*:*:*:*:*:*:* Versions 16.03.34.06 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac18:4.0:*:*:*:*:*:*:* Versions 4.0 Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-11120
  2. 2026-10-03 Alias added: GHSA-62cc-6mpf-6rxc
  3. 2026-10-18 EPSS moved to the 90th–95th percentile

References

  • TI-2024-37948 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP… CVSS 3.1CRITICAL 9.8
  • TI-2024-37947 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn… CVSS 3.1CRITICAL 9.8
  • TI-2024-37946 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName… CVSS 3.1CRITICAL 9.8
  • TI-2024-37945 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp… CVSS 3.1CRITICAL 9.8
  • TI-2024-37942 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter… CVSS 3.1CRITICAL 9.8
  • TI-2024-22327 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function. CVSS 3.1CRITICAL 9.8
See all 102 →

Sources