Read the docs
TI-2025-10373 Aliases CVE-2025-11325GHSA-5g8h-54w4-pmjh

Tenda AC18 fast_setting_pppoe_set stack-based overflow

Priority HIGH 73CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00817 57th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaAC1815.03.05.19(6318)—No fix listedCNA
  • AC18 VendorTenda Affected 15.03.05.19(6318) Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\(6318\):*:*:*:*:*:*:*15.03.05.19(6318)VulnerableTenda
cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\(6318\):*:*:*:*:*:*:* Versions 15.03.05.19(6318) Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-11325
  2. 2026-10-03 Alias added: GHSA-5g8h-54w4-pmjh

References

  • TI-2024-37948 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP… CVSS 3.1CRITICAL 9.8
  • TI-2024-37947 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn… CVSS 3.1CRITICAL 9.8
  • TI-2024-37946 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName… CVSS 3.1CRITICAL 9.8
  • TI-2024-37945 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp… CVSS 3.1CRITICAL 9.8
  • TI-2024-37942 Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter… CVSS 3.1CRITICAL 9.8
  • TI-2024-22327 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function. CVSS 3.1CRITICAL 9.8
See all 102 →

Sources