Read the docs
TI-2025-12158 Aliases CVE-2025-13294GHSA-w4wx-fgc2-5x27

Unauthenticated SQL injection in TBEA TLogger

Priority MEDIUM 43CWE-89Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
SQL injection
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-89.

Summary

An unauthenticated SQL injection vulnerability exists in the web server of TBEA TLogger V2.1.0.0B0.0.0.0. Multiple HTTP endpoints incorporate attacker-controlled parameters directly into SQLite queries without sufficient validation or parameterization. A remote unauthenticated attacker can exploit these endpoints to read, modify, or delete data stored in the device's CCU.db database.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00551 46th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TBEATBEA TLogger (TBEA Communication Box 3rd Generation)up to V2.1.0.0B0.0.0.0—No fix listedCNA
  • TBEA TLogger (TBEA Communication Box 3rd Generation) VendorTBEA Affected up to V2.1.0.0B0.0.0.0 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-13294
  2. 2026-10-03 Alias added: GHSA-w4wx-fgc2-5x27

References

  • TI-2025-12157 Backdoor / default root credentials CVSS 4.0CRITICAL 9.3
  • TI-2025-14300 Multiple Unauthenticated Denial-of-Service Conditions CVSS 4.0HIGH 8.8
  • TI-2025-14299 Unauthenticated Resource Exhaustion CVSS 4.0HIGH 8.7
  • TI-2025-14298 Insufficient Webserver Authentication CVSS 4.0CRITICAL 9.2
  • TI-2025-14297 Information Disclosure via UART CVSS 4.0LOW 2.4

Sources