Out-of-bounds read in Siemens Teamcenter Visualization V14.3
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Passive
- Attack complexity
- High
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 | before V14.3.0.13 | V14.3.0.13 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2312 | before V2312.0009 | V2312.0009 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2406 | before V2406.0007 | V2406.0007 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2412 | before V2412.0002 | V2412.0002 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2302 | before V2302.0021 | V2302.0021 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2404 | before V2404.0010 | V2404.0010 | Patch available | CNA |
- Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.13 Fixed in V14.3.0.13 Patch available CNA
- Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0009 Fixed in V2312.0009 Patch available CNA
- Teamcenter Visualization V2406 VendorSiemens Affected before V2406.0007 Fixed in V2406.0007 Patch available CNA
- Teamcenter Visualization V2412 VendorSiemens Affected before V2412.0002 Fixed in V2412.0002 Patch available CNA
- Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0021 Fixed in V2302.0021 Patch available CNA
- Tecnomatix Plant Simulation V2404 VendorSiemens Affected before V2404.0010 Fixed in V2404.0010 Patch available CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* | 14.0.0 to before 14.3.0.13; 2312.0 to before 2312.0009; 2412.0 to before 2412.0002 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* | 2302.0 to before 2302.0021; 2404.0 to before 2404.0010 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* Versions 14.0.0 to before 14.3.0.13; 2312.0 to before 2312.0009; 2412.0 to before 2412.0002 Vulnerable ·Siemens
- cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* Versions 2302.0 to before 2302.0021; 2404.0 to before 2404.0010 Vulnerable ·Siemens
Remediation
- Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.13
- Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0009
- Fix · CNA Teamcenter Visualization V2406 (Siemens) Fixed in V2406.0007
- Fix · CNA Teamcenter Visualization V2412 (Siemens) Fixed in V2412.0002
- Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0021
- Fix · CNA Tecnomatix Plant Simulation V2404 (Siemens) Fixed in V2404.0010
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Tecnomatix Plant Simulation V2302, Tecnomatix Plant Simulation V2404 V2302.0021, V2404.0010
10 records Highest priority Priority LOW 10 LOW
Other records, highest priority first
- TI-2025-20273 Out-of-bounds read in Siemens Teamcenter Visualization V14.3Priority LOW 33
- TI-2025-17170 Use after free in Siemens Teamcenter Visualization V14.3Priority LOW 33
- TI-2025-17168 Memory corruption in Siemens Teamcenter Visualization V14.3Priority LOW 33
- Release ·
Siemens Teamcenter Visualization V14.3, Teamcenter Visualization V2312 and 2 more products V14.3.0.13, V2312.0009 and 2 more versions
8 records Highest priority Priority LOW 8 LOW
Other records, highest priority first
- TI-2025-20273 Out-of-bounds read in Siemens Teamcenter Visualization V14.3Priority LOW 33
- TI-2025-17170 Use after free in Siemens Teamcenter Visualization V14.3Priority LOW 33
- TI-2025-17168 Memory corruption in Siemens Teamcenter Visualization V14.3Priority LOW 33
Timeline
- 2026-10-02 Threatist record created from CVE-2025-23401
- 2026-10-03 Alias added: GHSA-xwrr-h965-6hx9
References
More Siemens Teamcenter Visualization vulnerabilities
- TI-2020-16414 NULL pointer dereference in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16413 Type confusion in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16410 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16408 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16419 Out-of-bounds read in Siemens JT2Go CVSS 3.1HIGH 8.8
- TI-2020-16418 Out-of-bounds write in Siemens JT2Go CVSS 3.1HIGH 8.8
Sources
- CVE-2025-23401 · CVE Program
- CVE-2025-23401 · NVD
- FIRST EPSS
- GHSA-xwrr-h965-6hx9 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences