Incorrect input validation could allow an authenticated user to read sensitive information
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- SQL injection
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-89.
Summary
eLabFTW is an open source electronic lab notebook for research labs. Prior to version 5.1.15, an incorrect input validation could allow an authenticated user to read sensitive information, including login token or other content stored in the database. This could lead to privilege escalation if cookies are enabled (default setting). Users must upgrade to eLabFTW version 5.1.15 to receive a fix. No known workarounds are available.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
- Fix · CNA elabftw (elabftw) Fixed in 5.1.15
Timeline
- 2026-10-02 Threatist record created from CVE-2025-25206
References
More Elabftw vulnerabilities
- TI-2019-09101 eLabFTW 1.8.5 is vulnerable to arbitrary file uploads via the… CVSS 3.0HIGH 8.8
- TI-2022-13053 Privilege escalation from administrator in eLabFTW CVSS 3.1HIGH 7.2
- TI-2021-19640 Incorrect Authentication in elabftw CVSS 3.1CRITICAL 9.8
- TI-2021-18010 Bypass bruteforce protection on login form in elabftw CVSS 3.1HIGH 8.8
- TI-2021-19639 Account takeover in eLabFTW CVSS 3.1HIGH 8.8
- TI-2024-30457 eLabFTW contains a direct and indirect information disclosure CVSS 3.1HIGH 7.5
Sources