Read the docs
TI-2025-19430 Aliases CVE-2025-26483GHSA-883q-9j5h-3x3g

Open redirect in Dell PowerFlex Manager

Priority LOW 35CWE-601Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Spoofing
Confidentiality · integrity · availability
High · Low · None
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-601.

Summary

Dell PowerFlex Manager, versions 4.6.2 and prior, contains an Open Redirect Vulnerability. An unauthenticated attacker could potentially exploit this vulnerability, leading to a targeted application user being redirected to arbitrary web URLs. The vulnerability could be leveraged by attackers to conduct phishing attacks that cause users to divulge sensitive information.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00173 6th percentileScored 2026-11-07
Fix Fixed PowerFlex Manager (Appliance) (Dell): IC 48.378.00, IC 48.383.00PowerFlex Manager (Rack) (Dell): 3.7.8.0, 3.8.3.0

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
DellPowerFlex Manager (Appliance)before IC 48.378.00; before IC 48.383.00IC 48.378.00, IC 48.383.00Patch availableCNA
DellPowerFlex Manager (Rack)before 3.7.8.0; before 3.8.3.03.7.8.0, 3.8.3.0Patch availableCNA
DellPowerFlex Managerup to 4.6.2—No fix listedCNA
  • PowerFlex Manager (Appliance) VendorDell Affected before IC 48.378.00; before IC 48.383.00 Fixed in IC 48.378.00, IC 48.383.00 Patch available CNA
  • PowerFlex Manager (Rack) VendorDell Affected before 3.7.8.0; before 3.8.3.0 Fixed in 3.7.8.0, 3.8.3.0 Patch available CNA
  • PowerFlex Manager VendorDell Affected up to 4.6.2 Fixed in — No fix listed CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:dell:powerflex_appliance_intelligent_catalog:*:*:*:*:*:*:*:*before 48.383.00VulnerableDell
cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*up to 4.6.2VulnerableDell
cpe:2.3:a:dell:powerflex_rack:*:*:*:*:*:*:*:*before 3.7.8.0VulnerableDell
  • cpe:2.3:a:dell:powerflex_appliance_intelligent_catalog:*:*:*:*:*:*:*:* Versions before 48.383.00 Vulnerable ·Dell
  • cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:* Versions up to 4.6.2 Vulnerable ·Dell
  • cpe:2.3:a:dell:powerflex_rack:*:*:*:*:*:*:*:* Versions before 3.7.8.0 Vulnerable ·Dell

Remediation

  • Fix · CNA PowerFlex Manager (Appliance) (Dell) Fixed in IC 48.378.00, IC 48.383.00
  • Fix · CNA PowerFlex Manager (Rack) (Dell) Fixed in 3.7.8.0, 3.8.3.0

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Dell PowerFlex Manager, PowerFlex Manager (Appliance), PowerFlex Manager (Rack) — dell.com/support/kbdoc/en-us/000391392/dsa-2025-434-securit…

    8 records Highest priority Priority LOW 8 LOW

    Other records, highest priority first

    • TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through…Priority LOW 39
    • TI-2025-23802 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment…Priority LOW 33
    • TI-2025-23804 Incorrect default permissions in Dell PowerFlex ManagerPriority LOW 32
  • Advisory ·

    Dell PowerFlex Manager, PowerFlex Manager (Appliance), PowerFlex Manager (Rack) — dell.com/support/kbdoc/en-us/000391568/dsa-2025-435-securit…

    8 records Highest priority Priority LOW 8 LOW

    Other records, highest priority first

    • TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through…Priority LOW 39
    • TI-2025-23802 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment…Priority LOW 33
    • TI-2025-23804 Incorrect default permissions in Dell PowerFlex ManagerPriority LOW 32

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-26483
  2. 2026-10-03 Alias added: GHSA-883q-9j5h-3x3g

References

  • TI-2024-24670 Link following in Dell PowerFlex appliance CVSS 3.1CRITICAL 10.0
  • TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through… CVSS 3.1HIGH 7.5
  • TI-2024-24671 Insecure storage of sensitive information in Dell PowerFlex appliance CVSS 3.1HIGH 8.2
  • TI-2025-23802 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment… CVSS 3.1HIGH 7.8
  • TI-2025-23804 Incorrect default permissions in Dell PowerFlex Manager CVSS 3.1HIGH 7.5
  • TI-2025-23800 Improper certificate validation in Dell PowerFlex Manager CVSS 3.1MEDIUM 6.5
See all 9 →