Open redirect in Dell PowerFlex Manager
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Spoofing
- Confidentiality · integrity · availability
- High · Low · None
- Fix status
- Fixed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-601.
Summary
Dell PowerFlex Manager, versions 4.6.2 and prior, contains an Open Redirect Vulnerability. An unauthenticated attacker could potentially exploit this vulnerability, leading to a targeted application user being redirected to arbitrary web URLs. The vulnerability could be leveraged by attackers to conduct phishing attacks that cause users to divulge sensitive information.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Dell | PowerFlex Manager (Appliance) | before IC 48.378.00; before IC 48.383.00 | IC 48.378.00, IC 48.383.00 | Patch available | CNA |
| Dell | PowerFlex Manager (Rack) | before 3.7.8.0; before 3.8.3.0 | 3.7.8.0, 3.8.3.0 | Patch available | CNA |
| Dell | PowerFlex Manager | up to 4.6.2 | — | No fix listed | CNA |
- PowerFlex Manager (Appliance) VendorDell Affected before IC 48.378.00; before IC 48.383.00 Fixed in IC 48.378.00, IC 48.383.00 Patch available CNA
- PowerFlex Manager (Rack) VendorDell Affected before 3.7.8.0; before 3.8.3.0 Fixed in 3.7.8.0, 3.8.3.0 Patch available CNA
- PowerFlex Manager VendorDell Affected up to 4.6.2 Fixed in — No fix listed CNA
Remediation
- Fix · CNA PowerFlex Manager (Appliance) (Dell) Fixed in IC 48.378.00, IC 48.383.00
- Fix · CNA PowerFlex Manager (Rack) (Dell) Fixed in 3.7.8.0, 3.8.3.0
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Advisory ·
Dell PowerFlex Manager, PowerFlex Manager (Appliance), PowerFlex Manager (Rack) — dell.com/support/kbdoc/en-us/000391392/dsa-2025-434-securit…
8 records Highest priority Priority LOW 8 LOW
Other records, highest priority first
- TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through…Priority LOW 39
- TI-2025-23802 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment…Priority LOW 33
- TI-2025-23804 Incorrect default permissions in Dell PowerFlex ManagerPriority LOW 32
- Advisory ·
Dell PowerFlex Manager, PowerFlex Manager (Appliance), PowerFlex Manager (Rack) — dell.com/support/kbdoc/en-us/000391568/dsa-2025-435-securit…
8 records Highest priority Priority LOW 8 LOW
Other records, highest priority first
- TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through…Priority LOW 39
- TI-2025-23802 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment…Priority LOW 33
- TI-2025-23804 Incorrect default permissions in Dell PowerFlex ManagerPriority LOW 32
Timeline
- 2026-10-02 Threatist record created from CVE-2025-26483
- 2026-10-03 Alias added: GHSA-883q-9j5h-3x3g
References
Advisory 2
- https://www.dell.com/support/kbdoc/en-us/000391568/dsa-2025-435-security-update-for-dell-powerflex-rack-multiple-third-party-component-vulnerabilities
- https://www.dell.com/support/kbdoc/en-us/000391392/dsa-2025-434-security-update-for-dell-powerflex-appliance-multiple-third-party-component-vulnerabilities
More Dell Powerflex Appliance Intelligent Catalog vulnerabilities
- TI-2024-24670 Link following in Dell PowerFlex appliance CVSS 3.1CRITICAL 10.0
- TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through… CVSS 3.1HIGH 7.5
- TI-2024-24671 Insecure storage of sensitive information in Dell PowerFlex appliance CVSS 3.1HIGH 8.2
- TI-2025-23802 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment… CVSS 3.1HIGH 7.8
- TI-2025-23804 Incorrect default permissions in Dell PowerFlex Manager CVSS 3.1HIGH 7.5
- TI-2025-23800 Improper certificate validation in Dell PowerFlex Manager CVSS 3.1MEDIUM 6.5
Sources
- CVE-2025-26483 · CVE Program
- CVE-2025-26483 · NVD
- FIRST EPSS
- GHSA-883q-9j5h-3x3g · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences