Read the docs
TI-2025-19706 Aliases CVE-2025-26793GHSA-x8v9-7r66-c92w

The Web GUI configuration panel of Hirsch (formerly Identiv and Viscount) Enterphone MESH…

Priority MEDIUM 53CWE-1393Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

The Web GUI configuration panel of Hirsch (formerly Identiv and Viscount) Enterphone MESH through 2024 ships with default credentials (username freedom, password viscount). The administrator is not prompted to change these credentials on initial configuration, and changing the credentials requires many steps. Attackers can use the credentials over the Internet via mesh.webadmin.MESHAdminServlet to gain access to dozens of Canadian and U.S. apartment buildings and obtain building residents' PII. NOTE: the Supplier's perspective is that the "vulnerable systems are not following manufacturers' recommendations to change the default password."

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.02396 84th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
HirschEnterphone MESHup to 2024—No fix listedCNA
  • Enterphone MESH VendorHirsch Affected up to 2024 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-26793
  2. 2026-10-03 Alias added: GHSA-x8v9-7r66-c92w

References

Sources