Read the docs
TI-2025-20433 Aliases CVE-2025-27632GHSA-gv64-36xp-c47j

A Host Header Injection vulnerability in TRMTracker application may allow an attacker by…

Priority LOW 27CWE-644Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

A Host Header Injection vulnerability in TRMTracker application may allow an attacker by modifying the host header value in an HTTP request to leverage multiple attack vectors, including defacing the site content through web-cache poisoning.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.0025 16th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Hitachi EnergyTRMTracker6.2 – 6.2.04; 6.3 – 6.3.01—No fix listedCNA
  • TRMTracker VendorHitachi Energy Affected 6.2 – 6.2.04; 6.3 – 6.3.01 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Hitachi Energy TRMTracker — publisher.hitachienergy.com/preview?DocumentID=8DBD000210&L…

    3 records Highest priority Priority LOW 3 LOW

    Other records, highest priority first

    • TI-2025-20432 LDAP injection in Hitachi Energy TRMTrackerPriority LOW 35
    • TI-2025-20434 Cross-site scripting in Hitachi Energy TRMTrackerPriority LOW 27

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-27632
  2. 2026-10-03 Alias added: GHSA-gv64-36xp-c47j

References

  • TI-2019-03985 ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
  • TI-2018-10635 Improper authentication in ICS-CERT ABB eSOMS CVSS 3.0CRITICAL 9.8
  • TI-2024-01871 Heap-based buffer overflow in Hitachi Energy FOXMAN-UN CVSS 3.1CRITICAL 9.8
  • TI-2026-07105 Path traversal in Hitachi Energy RTU500 series CMU firmware CVSS 3.1CRITICAL 9.1
  • TI-2019-13270 Path traversal in Relion 670 Series CVSS 3.1CRITICAL 10.0
  • TI-2026-07104 Missing authentication in Hitachi Energy RTU500 series CMU firmware CVSS 3.1CRITICAL 9.1
See all 146 →