Read the docs
TI-2025-21147 Aliases CVE-2025-29628GHSA-82xm-jwxq-4436

Information disclosure in Gardyn Home Kit Firmware

Priority HIGH 82CWE-924Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure, Code execution
Confidentiality · integrity · availability
High · High · Low
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-200 and CWE-77.

Summary

A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00299 22nd percentileScored 2026-11-07
Fix Fixed Home Kit Firmware (Gardyn): master.619

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
GardynHome Kit Firmwarebefore master.619master.619Patch availableCNA
  • Home Kit Firmware VendorGardyn Affected before master.619 Fixed in master.619 Patch available CNA

Remediation

  • Fix · CNA Home Kit Firmware (Gardyn) Fixed in master.619

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Gardyn Home Kit Firmware master.619

    3 records Highest priority Priority HIGH 3 HIGH

    Other records, highest priority first

    • TI-2025-21149 OS command injection in Gardyn Home Kit FirmwarePriority HIGH 82
    • TI-2025-21148 Information disclosure in Gardyn Home Kit FirmwarePriority HIGH 74

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-29628
  2. 2026-10-03 Alias added: GHSA-82xm-jwxq-4436

References

  • TI-2025-21149 OS command injection in Gardyn Home Kit Firmware CVSS 3.1CRITICAL 9.8
  • TI-2025-21148 Information disclosure in Gardyn Home Kit Firmware CVSS 3.1CRITICAL 9.1
  • TI-2026-11608 Gardyn IoT Hub Use of Hard-coded Credentials CVSS 4.0CRITICAL 9.5
  • TI-2025-01062 Administrative Credentials Can Be Extracted Through Gardyn API Responses CVSS 4.0CRITICAL 9.3
  • TI-2026-20353 Gardyn Cloud API Authorization Bypass Through User-Controlled Key CVSS 4.0CRITICAL 9.3
  • TI-2026-22962 Gardyn Cloud API Missing Authentication for Critical Function CVSS 4.0CRITICAL 9.2
See all 12 →

Sources