TI-2025-23521 Aliases CVE-2025-32454GHSA-q7v7-jhxh-rv68

Out-of-bounds read in Siemens Teamcenter Visualization V14.3

Priority LOW 33CWE-125Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Passive
Attack complexity
High
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00182 7th percentileScored 2026-11-07
Fix Fixed Teamcenter Visualization V14.3 (Siemens): V14.3.0.14Teamcenter Visualization V2312 (Siemens): V2312.0010+3 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensTeamcenter Visualization V14.3before V14.3.0.14V14.3.0.14Patch availableCNA
SiemensTeamcenter Visualization V2312before V2312.0010V2312.0010Patch availableCNA
SiemensTeamcenter Visualization V2406before V2406.0008V2406.0008Patch availableCNA
SiemensTeamcenter Visualization V2412before V2412.0004V2412.0004Patch availableCNA
SiemensTecnomatix Plant Simulation V2404before V2404.0013V2404.0013Patch availableCNA
  • Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.14 Fixed in V14.3.0.14 Patch available CNA
  • Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0010 Fixed in V2312.0010 Patch available CNA
  • Teamcenter Visualization V2406 VendorSiemens Affected before V2406.0008 Fixed in V2406.0008 Patch available CNA
  • Teamcenter Visualization V2412 VendorSiemens Affected before V2412.0004 Fixed in V2412.0004 Patch available CNA
  • Tecnomatix Plant Simulation V2404 VendorSiemens Affected before V2404.0013 Fixed in V2404.0013 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*14.3 to before 14.3.0.14; 2312.0 to before 2312.0010; 2406.0 to before 2406.008; 2412.0 to before 2412.0004VulnerableSiemens
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*2404.0 to before 2404.0013VulnerableSiemens
  • cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* Versions 14.3 to before 14.3.0.14; 2312.0 to before 2312.0010; 2406.0 to before 2406.008; 2412.0 to before 2412.0004 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* Versions 2404.0 to before 2404.0013 Vulnerable ·Siemens

Remediation

  • Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.14
  • Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0010
  • Fix · CNA Teamcenter Visualization V2406 (Siemens) Fixed in V2406.0008
  • Fix · CNA Teamcenter Visualization V2412 (Siemens) Fixed in V2412.0004
  • Fix · CNA Tecnomatix Plant Simulation V2404 (Siemens) Fixed in V2404.0013

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-32454
  2. 2026-10-03 Alias added: GHSA-q7v7-jhxh-rv68

References

  • TI-2020-16414 NULL pointer dereference in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16413 Type confusion in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16410 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16408 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16419 Out-of-bounds read in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16418 Out-of-bounds write in Siemens JT2Go CVSS 3.1HIGH 8.8
See all 187 →

Sources