Read the docs
TI-2025-24359 Aliases CVE-2025-34210GHSA-2g9f-v599-7rv2

Vasion Print (formerly PrinterLogic) Readable Cleartext Passwords

Priority HIGH 76CWE-256Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-256.

Summary

Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA/SaaS deployments) store a large number of sensitive credentials (database passwords, MySQL root password, SaaS keys, Portainer admin password, etc.) in cleartext files that are world-readable. Any local user - or any process that can read the host filesystem - can retrieve all of these secrets in plain text, leading to credential theft and full compromise of the appliance. The vendor does not consider this to be a security vulnerability as this product "follows a shared responsibility model, where administrators are expected to configure persistent storage encryption."

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.0016 5th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
VasionPrint Virtual Appliance Hostall versions—No fix listedCNA
VasionPrint Applicationall versions—No fix listedCNA
  • Print Virtual Appliance Host VendorVasion Affected all versions Fixed in — No fix listed CNA
  • Print Application VendorVasion Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:vasion:virtual_appliance_application:-:*:*:*:*:*:*:*not specified by NVDVulnerableVasion
cpe:2.3:a:vasion:virtual_appliance_host:-:*:*:*:*:*:*:*not specified by NVDVulnerableVasion
  • cpe:2.3:a:vasion:virtual_appliance_application:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Vasion
  • cpe:2.3:a:vasion:virtual_appliance_host:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Vasion

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-34210
  2. 2026-10-03 Alias added: GHSA-2g9f-v599-7rv2

References

  • TI-2025-24370 Vasion Print (formerly PrinterLogic) Unauthenticated Device Modification CVSS 4.0CRITICAL 10.0
  • TI-2025-24369 Vasion Print (formerly PrinterLogic) Insecure Installation Credentials CVSS 4.0CRITICAL 10.0
  • TI-2025-24368 Vasion Print (formerly PrinterLogic) Unauthenticated Admin APIs Used to Modify SSL Certificates CVSS 4.0CRITICAL 10.0
  • TI-2025-24367 Missing authentication in Vasion Print Virtual Appliance Host CVSS 4.0CRITICAL 10.0
  • TI-2025-24364 Vasion Print (formerly PrinterLogic) Undocumented Hardcoded SSH Key CVSS 4.0CRITICAL 10.0
  • TI-2025-24363 Vasion Print (formerly PrinterLogic) RCE and Password Leaks via API CVSS 4.0CRITICAL 10.0
See all 42 →

Sources