Ericsson Indoor Connect 8855 - Improper Input Validation Vulnerability
Priority MEDIUM 40CWE-20Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
Ericsson Indoor Connect 8855 contains an improper input validation vulnerability which if exploited can allow an attacker to execute commands with escalated privileges.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00427 37th percentileScored 2026-11-07
Fix Fixed Indoor Connect 8855 (Ericsson): 2025.Q2
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Ericsson | Indoor Connect 8855 | before 2025.Q2 | 2025.Q2 | Patch available | CNA |
- Indoor Connect 8855 VendorEricsson Affected before 2025.Q2 Fixed in 2025.Q2 Patch available CNA
Remediation
- Fix · CNA Indoor Connect 8855 (Ericsson) Fixed in 2025.Q2
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Ericsson Indoor Connect 8855 2025.Q2
5 records Highest priority Priority MEDIUM 3 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2025-20109 Ericsson Indoor Connect 8855 - Improper Neutralization of Special Elements used in an OS Command VulnerabilityPriority MEDIUM 40
- TI-2025-20108 Ericsson Indoor Connect 8855 - Improper Neutralization of Special Elements used in an SQL Command VulnerabilityPriority MEDIUM 40
- TI-2025-27273 Ericsson Indoor Connect 8855 - Missing Authorization VulnerabilityPriority LOW 39
Timeline
- 2026-10-02 Threatist record created from CVE-2025-40836
- 2026-10-03 Alias added: GHSA-72r9-6vhw-cpmr
References
More Ericsson Indoor Connect 8855 Firmware vulnerabilities
- TI-2025-27276 Ericsson Indoor Connect 8855 - Improper Neutralization of Input During Web Page Generation Vulnerability CVSS 4.0HIGH 8.5
- TI-2025-20109 Ericsson Indoor Connect 8855 - Improper Neutralization of Special Elements used in an OS Command Vulnerability CVSS 4.0HIGH 8.5
- TI-2025-20108 Ericsson Indoor Connect 8855 - Improper Neutralization of Special Elements used in an SQL Command Vulnerability CVSS 4.0HIGH 8.7
- TI-2025-27273 Ericsson Indoor Connect 8855 - Missing Authorization Vulnerability CVSS 4.0HIGH 8.7
- TI-2025-20107 Ericsson Indoor Connect 8855 - Improper Filtering of Special Elements Vulnerability CVSS 4.0HIGH 7.2
- TI-2025-27274 Ericsson Indoor Connect 8855 - Insufficiently Protected Credentials Vulnerability CVSS 4.0MEDIUM 5.1
Sources
- CVE-2025-40836 · CVE Program
- CVE-2025-40836 · NVD
- FIRST EPSS
- GHSA-72r9-6vhw-cpmr · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences