Read the docs
TI-2025-29327 Aliases CVE-2025-46626GHSA-gc4p-7qxx-hhrw

Reuse of a static AES key and initialization vector for encrypted traffic to the 'ate'…

Priority LOW 32CWE-326Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-326.

Summary

Reuse of a static AES key and initialization vector for encrypted traffic to the 'ate' management service of the Tenda RX2 Pro 16.03.30.14 allows an attacker to decrypt, replay, and/or forge traffic to the service.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00238 14th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:*16.03.30.14VulnerableTenda
cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:* Versions 16.03.30.14 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-46626
  2. 2026-10-03 Alias added: GHSA-gc4p-7qxx-hhrw

References

  • TI-2025-29326 Lack of input validation/sanitization in the 'setLanCfg' API endpoint in httpd in the… CVSS 3.1HIGH 8.8
  • TI-2025-29332 Improper access controls in the web management portal of the Tenda RX2 Pro 16.03.30.14… CVSS 3.1MEDIUM 6.5
  • TI-2025-29329 Lack of input validation/sanitization in the 'ate' management service in the Tenda RX2… CVSS 3.1HIGH 7.3
  • TI-2025-29328 Use of weak credentials in the Tenda RX2 Pro 16.03.30.14 allows an unauthenticated… CVSS 3.1HIGH 8.2
  • TI-2025-29335 Cleartext transmission of sensitive information in the web management portal of the Tenda… CVSS 3.1HIGH 8.2
  • TI-2025-29334 Cleartext transmission of sensitive information in the web management portal of the Tenda… CVSS 3.1HIGH 8.2
See all 10 →

Sources