Initialization vector (IV) reuse in the web management portal of the Tenda RX2 Pro…

Priority LOW 29CWE-323Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA.

Summary

Initialization vector (IV) reuse in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an attacker to discern information about or more easily decrypt encrypted messages between client and server.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00322 25th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:*16.03.30.14VulnerableTenda
cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:* Versions 16.03.30.14 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-46632
  2. 2026-10-03 Alias added: GHSA-wf34-hx5v-vq6q

References

  • TI-2025-29326 Lack of input validation/sanitization in the 'setLanCfg' API endpoint in httpd in the… CVSS 3.1HIGH 8.8
  • TI-2025-29332 Improper access controls in the web management portal of the Tenda RX2 Pro 16.03.30.14… CVSS 3.1MEDIUM 6.5
  • TI-2025-29329 Lack of input validation/sanitization in the 'ate' management service in the Tenda RX2… CVSS 3.1HIGH 7.3
  • TI-2025-29328 Use of weak credentials in the Tenda RX2 Pro 16.03.30.14 allows an unauthenticated… CVSS 3.1HIGH 8.2
  • TI-2025-29335 Cleartext transmission of sensitive information in the web management portal of the Tenda… CVSS 3.1HIGH 8.2
  • TI-2025-29334 Cleartext transmission of sensitive information in the web management portal of the Tenda… CVSS 3.1HIGH 8.2
See all 10 →

Sources