Authentication bypass in Schweitzer Engineering Laboratories SEL-3350-1
Priority LOW 20CWE-305Published · Updated
Key facts
- Attack vector
- Local
- Privileges required
- High
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- None · High · None
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA.
Summary
SEL BIOS packages prior to 1.3.49152.117 or 2.6.49152.98 allow a local attacker to bypass password authentication and change password-protected BIOS settings by importing a BIOS settings file with no password set.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00172 6th percentileScored 2026-11-07
Fix Fixed SEL-3350-1 (Schweitzer Engineering Laboratories): 1.3.49152.117SEL-3355-2 (Schweitzer Engineering Laboratories): 2.6.49152.98+1 more product
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Schweitzer Engineering Laboratories | SEL-3350-1 | before 1.3.49152.117 | 1.3.49152.117 | Patch available | CNA |
| Schweitzer Engineering Laboratories | SEL-3355-2 | before 2.6.49152.98 | 2.6.49152.98 | Patch available | CNA |
| Schweitzer Engineering Laboratories | SEL-3360-2 | before 2.6.49152.98 | 2.6.49152.98 | Patch available | CNA |
- SEL-3350-1 VendorSchweitzer Engineering Laboratories Affected before 1.3.49152.117 Fixed in 1.3.49152.117 Patch available CNA
- SEL-3355-2 VendorSchweitzer Engineering Laboratories Affected before 2.6.49152.98 Fixed in 2.6.49152.98 Patch available CNA
- SEL-3360-2 VendorSchweitzer Engineering Laboratories Affected before 2.6.49152.98 Fixed in 2.6.49152.98 Patch available CNA
Remediation
- Fix · CNA SEL-3350-1 (Schweitzer Engineering Laboratories) Fixed in 1.3.49152.117
- Fix · CNA SEL-3355-2 (Schweitzer Engineering Laboratories) Fixed in 2.6.49152.98
- Fix · CNA SEL-3360-2 (Schweitzer Engineering Laboratories) Fixed in 2.6.49152.98
Timeline
- 2026-10-02 Threatist record created from CVE-2025-46750
- 2026-10-03 Alias added: GHSA-9j22-g5g3-cw39
References
More Schweitzer Engineering Laboratories vulnerabilities
- TI-2023-14886 Insufficient entropy vulnerability could lead to authentication bypass CVSS 3.1CRITICAL 9.8
- TI-2018-07489 XML external entity injection in Schweitzer Engineering Laboratories AcSELerator Architect CVSS 3.0CRITICAL 9.8
- TI-2017-05537 Improper access control in Schweitzer Engineering Laboratories, Inc. SEL-3620 and SEL-3622 CVSS 3.0CRITICAL 10.0
- TI-2023-17218 Improper authentication could lead to session hijacking CVSS 3.1CRITICAL 9.8
- TI-2023-14885 Execution with Unnecessary Privileges CVSS 3.1CRITICAL 9.8
- TI-2023-14859 Improper Input Validation in Web Interface CVSS 3.1CRITICAL 9.1
Sources
- CVE-2025-46750 · CVE Program
- CVE-2025-46750 · NVD
- FIRST EPSS
- GHSA-9j22-g5g3-cw39 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences