Read the docs
TI-2025-31231 Aliases CVE-2025-49151GHSA-qcp5-jccp-3p6h

Use of Hard-coded, Security-relevant Constants in MICROSENS NMP Web+

Priority MEDIUM 49CWE-547Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

The affected products could allow an unauthenticated attacker to generate forged JSON Web Tokens (JWT) to bypass authentication.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00599 48th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
MicrosensNMP Web+up to Version 3.2.5—No fix listedCNA
  • NMP Web+ VendorMicrosens Affected up to Version 3.2.5 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-49151
  2. 2026-10-03 Alias added: GHSA-qcp5-jccp-3p6h

References

  • TI-2025-31233 Path Traversal in MICROSENS NMP Web+ CVSS 4.0CRITICAL 9.3
  • TI-2025-31232 Insufficient Session Expiration in MICROSENS NMP Web+ CVSS 4.0HIGH 8.7