Multiple buffer overflows in the SetClientState function of Tenda AC6 v.15.03.06.50…
Priority LOW 39CWE-120Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Denial of service
- Confidentiality · integrity · availability
- None · None · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-120 and the CVSS impact.
Summary
Multiple buffer overflows in the SetClientState function of Tenda AC6 v.15.03.06.50 allows attackers to cause a Denial of Service (DoS) via injecting a crafted payload into the limitSpeed, deviceId, and limitSpeedUp parameters.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00407 35th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2025-60340
- 2026-10-03 Alias added: GHSA-6wm4-jm7f-g22c
References
More Tenda Ac6 Firmware vulnerabilities
- TI-2025-20961 Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. CVSS 3.1CRITICAL 9.8
- TI-2023-20197 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
- TI-2023-20196 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0… CVSS 3.1CRITICAL 9.8
- TI-2023-20193 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0… CVSS 3.1CRITICAL 9.8
- TI-2023-20191 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
- TI-2023-20109 Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2025-60340 · CVE Program
- CVE-2025-60340 · NVD
- FIRST EPSS
- GHSA-6wm4-jm7f-g22c · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences