Read the docs
TI-2025-39573 Aliases CVE-2025-64122GHSA-2hrm-3727-3mc5

Nuvation Energy Multi-Stack Controller Private Key Stored on Device

Priority LOW 30CWE-522Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
High
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
None · High · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-522.

Summary

Insufficiently Protected Credentials vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Signature Spoofing by Key Theft.This issue affects Multi-Stack Controller (MSC): through 2.5.1.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00094 0th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Nuvation EnergyMulti-Stack Controller (MSC)up to 2.5.1—No fix listedCNA
  • Multi-Stack Controller (MSC) VendorNuvation Energy Affected up to 2.5.1 Fixed in — No fix listed CNA

CPE configurations NVD · 5

CPEVersionsRoleVendor
cpe:2.3:a:nuvationenergy:nplatform:*:*:*:*:*:*:*:*up to 2.5.1VulnerableNuvation Energy
cpe:2.3:h:nuvationenergy:nuvmsc3-04s-c:-:*:*:*:*:*:*:*not specified by NVDRunning onNuvation Energy
cpe:2.3:h:nuvationenergy:nuvmsc3-08s-c:-:*:*:*:*:*:*:*not specified by NVDRunning onNuvation Energy
cpe:2.3:h:nuvationenergy:nuvmsc3-12s-c:-:*:*:*:*:*:*:*not specified by NVDRunning onNuvation Energy
cpe:2.3:h:nuvationenergy:nuvmsc3-16s-c:-:*:*:*:*:*:*:*not specified by NVDRunning onNuvation Energy
  • cpe:2.3:a:nuvationenergy:nplatform:*:*:*:*:*:*:*:* Versions up to 2.5.1 Vulnerable ·Nuvation Energy
  • cpe:2.3:h:nuvationenergy:nuvmsc3-04s-c:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Nuvation Energy
  • cpe:2.3:h:nuvationenergy:nuvmsc3-08s-c:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Nuvation Energy
  • cpe:2.3:h:nuvationenergy:nuvmsc3-12s-c:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Nuvation Energy
  • cpe:2.3:h:nuvationenergy:nuvmsc3-16s-c:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Nuvation Energy

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-64122
  2. 2026-10-03 Alias added: GHSA-2hrm-3727-3mc5

References

  • TI-2025-39572 Nuvation Energy Multi-Stack Controller Authentication Bypass CVSS 4.0CRITICAL 10.0
  • TI-2025-39571 Nuvation Energy Multi-Stack Controller OS Command Injection CVSS 4.0CRITICAL 9.4
  • TI-2025-39575 Nuvation Energy Multi-Stack Controller OS Command Injection CVSS 4.0HIGH 8.7
  • TI-2025-39574 Nuvation Energy Multi-Stack Controller Proxy service allows arbitrary BMS access CVSS 4.0HIGH 7.9

Sources