Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-798.
Summary
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| RUCKUS Networks | vRIoT IOT Controller | 2.3.0.0 (GA) to before 3.0.0.0 (GA); 2.3.1.0 (MR) to before 3.0.0.0 (GA); 2.4.0.0 (GA) to before 3.0.0.0 (GA) | 3.0.0.0 (GA) | Patch available | CNA |
- vRIoT IOT Controller VendorRUCKUS Networks Affected 2.3.0.0 (GA) to before 3.0.0.0 (GA); 2.3.1.0 (MR) to before 3.0.0.0 (GA); 2.4.0.0 (GA) to before 3.0.0.0 (GA) Fixed in 3.0.0.0 (GA) Patch available CNA
Remediation
- Fix · CNA vRIoT IOT Controller (RUCKUS Networks) Fixed in 3.0.0.0 (GA)
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Advisory ·
RUCKUS Networks vRIoT IOT Controller — support.ruckuswireless.com/security_bulletins/336
2 records Highest priority Priority MEDIUM 2 MEDIUM
Other records, highest priority first
- TI-2025-42865 Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded Tokens RCEPriority MEDIUM 50
Timeline
- 2026-10-02 Threatist record created from CVE-2025-69426
- 2026-10-03 Alias added: GHSA-q3qv-m4mc-pj49
References
More RUCKUS Networks vulnerabilities
- TI-2025-42865 Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded Tokens RCE CVSS 4.0CRITICAL 10.0
- TI-2023-06704 Ruckus Unleashed Authenticated RCE in Gateway Mode CVSS 4.0HIGH 7.7
Sources
- CVE-2025-69426 · CVE Program
- CVE-2025-69426 · NVD
- FIRST EPSS
- GHSA-q3qv-m4mc-pj49 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences