Read the docs
TI-2025-42866 Aliases CVE-2025-69426GHSA-q3qv-m4mc-pj49

Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE

Priority MEDIUM 49CWE-732Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-798.

Summary

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00393 33rd percentileScored 2026-11-07
Fix Fixed vRIoT IOT Controller (RUCKUS Networks): 3.0.0.0 (GA)

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
RUCKUS NetworksvRIoT IOT Controller2.3.0.0 (GA) to before 3.0.0.0 (GA); 2.3.1.0 (MR) to before 3.0.0.0 (GA); 2.4.0.0 (GA) to before 3.0.0.0 (GA)3.0.0.0 (GA)Patch availableCNA
  • vRIoT IOT Controller VendorRUCKUS Networks Affected 2.3.0.0 (GA) to before 3.0.0.0 (GA); 2.3.1.0 (MR) to before 3.0.0.0 (GA); 2.4.0.0 (GA) to before 3.0.0.0 (GA) Fixed in 3.0.0.0 (GA) Patch available CNA

Remediation

  • Fix · CNA vRIoT IOT Controller (RUCKUS Networks) Fixed in 3.0.0.0 (GA)

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    RUCKUS Networks vRIoT IOT Controller — support.ruckuswireless.com/security_bulletins/336

    2 records Highest priority Priority MEDIUM 2 MEDIUM

    Other records, highest priority first

    • TI-2025-42865 Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded Tokens RCEPriority MEDIUM 50

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-69426
  2. 2026-10-03 Alias added: GHSA-q3qv-m4mc-pj49

References

  • TI-2025-42865 Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded Tokens RCE CVSS 4.0CRITICAL 10.0
  • TI-2023-06704 Ruckus Unleashed Authenticated RCE in Gateway Mode CVSS 4.0HIGH 7.7