Read the docs
TI-2026-02036 Aliases CVE-2026-2402GHSA-gwjq-j584-rm32

Missing brute-force protection in Schneider Electric PowerChute™ Serial Shutdown

Priority LOW 36CWE-307Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
None · None · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-307.

Summary

CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00274 19th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricPowerChute™ Serial Shutdownup to v1.4—No fix listedCNA
  • PowerChute™ Serial Shutdown VendorSchneider Electric Affected up to v1.4 Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:powerchute_serial_shutdown:*:*:*:*:*:*:*:*before 1.5VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:powerchute_serial_shutdown:*:*:*:*:*:*:*:* Versions before 1.5 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-2402
  2. 2026-10-03 Alias added: GHSA-gwjq-j584-rm32

References

  • TI-2026-02038 Improper output encoding in Schneider Electric PowerChute™ Serial Shutdown CVSS 4.0MEDIUM 6.9
  • TI-2026-02033 Path traversal in Schneider Electric PowerChute™ Serial Shutdown CVSS 4.0MEDIUM 6.9
  • TI-2026-02039 Uncontrolled resource consumption in Schneider Electric PowerChute™ Serial Shutdown CVSS 4.0MEDIUM 5.3
  • TI-2026-02034 CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists… CVSS 4.0MEDIUM 5.3
  • TI-2026-02037 CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that… CVSS 4.0MEDIUM 5.3
  • TI-2026-02035 Sensitive information in log files in Schneider Electric PowerChute™ Serial Shutdown CVSS 4.0LOW 2.4

Sources