Read the docs
TI-2026-02501 Aliases CVE-2026-2908GHSA-2665-m8rg-c7xp

Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow

Priority HIGH 79CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00646 51st percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaHG9300001138—No fix listedCNA
  • HG9 VendorTenda Affected 300001138 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:hg9_firmware:300001138:*:*:*:*:*:*:*300001138VulnerableTenda
cpe:2.3:h:tenda:hg9:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:hg9_firmware:300001138:*:*:*:*:*:*:* Versions 300001138 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:hg9:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-2908
  2. 2026-10-03 Alias added: GHSA-2665-m8rg-c7xp

References

  • TI-2026-02502 Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-02503 Tenda HG9 formPing6 stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-02500 Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-02499 Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-02498 Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2022-12351 Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. CVSS 3.1HIGH 8.8

Sources