Read the docs
TI-2026-03410 Aliases CVE-2026-3943GHSA-2xx3-8jg7-cq2x

H3C ACG1000-AK230 aaa_portal_auth_local_submit command injection

Priority HIGH 70CWE-74Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.

Summary

A vulnerability was found in H3C ACG1000-AK230 up to 20260227. This affects an unknown part of the file /webui/?aaa_portal_auth_local_submit. The manipulation of the argument suffix results in command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor is investigating and remediating this issue.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.42588 98th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
H3CACG1000-AK23020260227—No fix listedCNA
  • ACG1000-AK230 VendorH3C Affected 20260227 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-3943
  2. 2026-10-03 Alias added: GHSA-2xx3-8jg7-cq2x
  3. 2026-10-25 EPSS moved to the 95th–99th percentile

References

  • TI-2025-37618 An issue in H3C M102G HM1A0V200R010 wireless controller and BA1500L SWBA1A0V100R006… CVSS 3.1CRITICAL 9.8
  • TI-2024-35290 H3C GR-1800AX MiniGRW1B0V100R007 is vulnerable to remote code execution (RCE) via the aspForm parameter. CVSS 3.1CRITICAL 9.8
  • TI-2024-28559 H3C GR1100-P v100R009 was discovered to use a hardcoded password in /etc/shadow, which… CVSS 3.1CRITICAL 9.8
  • TI-2024-28557 H3C R3010 v100R002L02 was discovered to contain a hardcoded password vulnerability in… CVSS 3.1CRITICAL 9.8
  • TI-2023-13966 H3C GR-1200W MiniGRW1A0V100R006 was discovered to contain a stack overflow via the function version_set. CVSS 3.1CRITICAL 9.8
  • TI-2023-13965 H3C GR-1200W MiniGRW1A0V100R006 was discovered to contain a stack overflow via the function set_tftp_upgrad. CVSS 3.1CRITICAL 9.8
See all 228 →

Sources