ChargePoint Home Flex Inclusion of Sensitive Information in Source Code Information…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · CNA. Fix status from CNA.
Summary
ChargePoint Home Flex Inclusion of Sensitive Information in Source Code Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the genpw script. The issue results from the inclusion of a secret cryptographic seed value within the script. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-26340.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| ChargePoint | Home Flex | 5.5.4.13 | — | No fix listed | CNA |
- Home Flex VendorChargePoint Affected 5.5.4.13 Fixed in — No fix listed CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:chargepoint:home_flex_cph50_firmware:*:*:*:*:*:*:*:* | before 5.5.4.22 | Vulnerable | ChargePoint |
| cpe:2.3:h:chargepoint:home_flex_cph50:-:*:*:*:*:*:*:* | not specified by NVD | Running on | ChargePoint |
- cpe:2.3:o:chargepoint:home_flex_cph50_firmware:*:*:*:*:*:*:*:* Versions before 5.5.4.22 Vulnerable ·ChargePoint
- cpe:2.3:h:chargepoint:home_flex_cph50:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·ChargePoint
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2026-4155
- 2026-10-03 Alias added: GHSA-69j2-hc78-98c7
- 2026-10-25 EPSS moved to the below the 50th percentile
References
Advisory 1
More ChargePoint Home Flex Cph50 Firmware vulnerabilities
- TI-2026-03605 OS command injection in ChargePoint Home Flex CVSS 3.0HIGH 7.5
- TI-2026-03604 Stack-based buffer overflow in ChargePoint Home Flex CVSS 3.0HIGH 7.5
Sources
- CVE-2026-4155 · CVE Program
- CVE-2026-4155 · NVD
- FIRST EPSS
- GHSA-69j2-hc78-98c7 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences