Read the docs
TI-2026-03717 Aliases CVE-2026-4272GHSA-396r-wg2m-qxg7

CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability

Priority LOW 36CWE-306Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · None
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-306.

Summary

Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA. This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned  CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00664 51st percentileScored 2026-11-07
Fix Fixed Barcode Scanners (Honeywell): GK000432BAA, HE000085BAA, BK000763BAA_BK000765BAA_CU000101BAA

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
HoneywellBarcode ScannersC1 Base(Ingenic x1000) to before GK000432BAA; D1 Base(Ingenic x1600) to before HE000085BAA; A1/B1 Base(IMX25) to before BK000763BAA_BK000765BAA_CU000101BAAGK000432BAA, HE000085BAA, BK000763BAA_BK000765BAA_CU000101BAAPatch availableCNA
  • Barcode Scanners VendorHoneywell Affected C1 Base(Ingenic x1000) to before GK000432BAA; D1 Base(Ingenic x1600) to before HE000085BAA; A1/B1 Base(IMX25) to before BK000763BAA_BK000765BAA_CU000101BAA Fixed in GK000432BAA, HE000085BAA, BK000763BAA_BK000765BAA_CU000101BAA Patch available CNA

Remediation

  • Fix · CNA Barcode Scanners (Honeywell) Fixed in GK000432BAA, HE000085BAA, BK000763BAA_BK000765BAA_CU000101BAA

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-4272
  2. 2026-10-03 Alias added: GHSA-396r-wg2m-qxg7
  3. 2026-10-25 EPSS moved to the 50th–90th percentile

References

  • TI-2023-03466 Printer web page invalid command execution CVSS 3.1CRITICAL 9.9
  • TI-2021-22482 WIN-PACK PRO 4.8 - 'WPCommandFileService' Unquoted Service Path CVSS 4.0HIGH 8.5
  • TI-2021-22480 WIN-PACK PRO 4.8 - 'GuardTourService' Unquoted Service Path CVSS 4.0HIGH 8.5
  • TI-2007-02844 Buffer overflow in the BaseRunner ActiveX control in the Ademco ATNBaseLoader100 Module… CVSS 2.0HIGH 10.0
  • TI-2023-18324 MAS (a Carrier brand) MASmobile Classic Authorization Bypass CVSS 3.1MEDIUM 6.5
  • TI-2023-28253 XML external entity injection in Honeywell Saia PG5 Controls Suite CVSS 3.1MEDIUM 6.5