Read the docs
TI-2026-04546 Aliases CVE-2026-5204GHSA-5qj8-jcmc-3p6q

Tenda CH22 Parameter webtypelibrary formWebTypeLibrary stack-based overflow

Priority HIGH 73CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A vulnerability was determined in Tenda CH22 1.0.0.1. Affected is the function formWebTypeLibrary of the file /goform/webtypelibrary of the component Parameter Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.02519 84th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaCH221.0.0.1—No fix listedCNA
  • CH22 VendorTenda Affected 1.0.0.1 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ch22_firmware:1.0.0.1:*:*:*:*:*:*:*1.0.0.1VulnerableTenda
cpe:2.3:h:tenda:ch22:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:ch22_firmware:1.0.0.1:*:*:*:*:*:*:* Versions 1.0.0.1 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ch22:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-5204
  2. 2026-10-03 Alias added: GHSA-5qj8-jcmc-3p6q

References

  • TI-2025-10464 Tenda CH22 SafeEmailFilter formSafeEmailFilter memory corruption CVSS 4.0CRITICAL 9.3
  • TI-2025-10459 Tenda CH22 HTTP Request AdvSetWrlsafeset formWrlsafeset stack-based overflow CVSS 4.0CRITICAL 9.3
  • TI-2024-30869 Tenda CH22 V1.0.0.6(468) has a stack overflow vulnerability located in the frmL7PlotForm function. CVSS 3.1CRITICAL 9.8
  • TI-2024-30868 CH22 V1.0.0.6(468) has a stack overflow vulnerability located in the fromqossetting function. CVSS 3.1CRITICAL 9.8
  • TI-2026-04913 Tenda CH22 WrlExtraSet formWrlExtraSet stack-based overflow CVSS 4.0HIGH 8.7
  • TI-2026-04912 Tenda CH22 Parameter CertLocalPrecreate formCertLocalPrecreate stack-based overflow CVSS 4.0HIGH 8.7
See all 38 →

Sources