Read the docs
TI-2026-07077 Aliases CVE-2026-8031GHSA-9853-g727-5v8x

PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication

Priority HIGH 70CWE-287Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
Low · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-287.

Summary

A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00394 33rd percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA
Fix Fixed e-Clinic Healthcare System ECHS (PicoTronica): 5.7.1

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
PicoTronicae-Clinic Healthcare System ECHS5.75.7.1Patch availableCNA
  • e-Clinic Healthcare System ECHS VendorPicoTronica Affected 5.7 Fixed in 5.7.1 Patch available CNA

Remediation

  • Fix · CNA e-Clinic Healthcare System ECHS (PicoTronica) Fixed in 5.7.1

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-8031
  2. 2026-10-03 Alias added: GHSA-9853-g727-5v8x
  3. 2026-10-25 EPSS moved to the below the 50th percentile

References

  • TI-2026-07079 PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure CVSS 4.0MEDIUM 6.9
  • TI-2026-07078 PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials CVSS 4.0MEDIUM 6.9

Sources