Read the docs
TI-2026-07284 Aliases CVE-2026-8264GHSA-2fpj-h75c-c5vr

Tenda AC6 httpd WifiApScan formWifiApScan os command injection

Priority MEDIUM 57CWE-77Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.

Summary

A weakness has been identified in Tenda AC6 15.03.06.23. Affected by this vulnerability is the function formWifiApScan of the file /goform/WifiApScan of the component httpd. Executing a manipulation of the argument wl2g.public.country/wl5g.public.country can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.03178 88th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaAC615.03.06.23—No fix listedCNA
  • AC6 VendorTenda Affected 15.03.06.23 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*15.03.06.23VulnerableTenda
cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*2.0Running onTenda
  • cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:* Versions 15.03.06.23 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:* Versions 2.0 Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-8264
  2. 2026-10-03 Alias added: GHSA-2fpj-h75c-c5vr
  3. 2026-10-25 EPSS moved to the 50th–90th percentile

References

  • TI-2025-20961 Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. CVSS 3.1CRITICAL 9.8
  • TI-2023-20197 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20196 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20193 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20191 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20109 Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0… CVSS 3.1CRITICAL 9.8
See all 107 →

Sources