Read the docs
TI-2026-07285 Aliases CVE-2026-8265GHSA-qvqp-rwfh-7f5j

Tenda AC6 httpd getLogFile get_log_file os command injection

Priority MEDIUM 56CWE-77Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.

Summary

A security vulnerability has been detected in Tenda AC6 15.03.06.23. Affected by this issue is the function get_log_file of the file /goform/getLogFile of the component httpd. The manipulation of the argument wans.flag leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.04848 92nd percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaAC615.03.06.23—No fix listedCNA
  • AC6 VendorTenda Affected 15.03.06.23 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*15.03.06.23VulnerableTenda
cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*2.0Running onTenda
  • cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:* Versions 15.03.06.23 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:* Versions 2.0 Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-8265
  2. 2026-10-03 Alias added: GHSA-qvqp-rwfh-7f5j

References

  • TI-2025-20961 Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. CVSS 3.1CRITICAL 9.8
  • TI-2023-20197 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20196 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20193 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20191 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20109 Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0… CVSS 3.1CRITICAL 9.8
See all 107 →